Specification Matrix

Comparative Material Performance Matrix

Select 2 to 4 glass constructions to compare mechanical properties, regulatory classifications, and processing limits.

Performance Property
Toughened Safety Glass (Tempered)BS EN 12150-1
Laminated Safety & Security GlassBS EN 14449
Insulating Glass Units (Double & Triple IGUs)BS EN 1279 (Parts 1–6)
Safety Classification (EN 12600)Class 1C1 (BS EN 12600)Class 1B1 or 2B2 (BS EN 12600)Determined by individual glass plies (inner/outer toughened or laminated)
Mechanical Bending Strength4 to 5 times stronger in bending than annealed float (characteristic bending strength 120 N/mm²)Equivalent to constituent panes; structural ionoplast interlayers achieve post-yield load capacityShares wind load between plies via cavity pressure transfer; calculated per EN 16612
Post-Breakage ContainmentDisintegrates into small, relatively blunt granular dice, drastically reducing laceration riskGlass panes crack upon high impact but fragments adhere tenaciously to interlayer; aperture remains sealedDepends on selected plies; safety glass required on inner or outer depending on impact zone
Typical Thermal Ug (W/m²K)5.7 W/m²K (single glazed monolithic) — requires IGU assembly for thermal efficiency5.4 W/m²K to 5.7 W/m²K monolithic; 1.0 to 1.4 W/m²K in sealed units1.0 to 1.2 W/m²K (Double Glazed 28mm Argon + Soft Coat Low-E); 0.5 to 0.7 W/m²K (Triple Glazed 44mm Krypton)
Acoustic Reduction (Rw dB)Rw 29 dB (4mm) to Rw 35 dB (12mm)Rw 33 dB to Rw 42 dB (acoustic PVB achieves +3 to +5 dB reduction over monolithic)Rw 31 dB (standard 4-16-4) up to Rw 46 dB (dissimilar thicknesses + acoustic laminated pane)
Solar Factor (g-value)Conditional / Base Float (~0.85)Conditional / Base Float (~0.85)0.28 to 0.65 depending on Low-E vs Solar Control coating selection
Can Be Cut / Drilled After Fabrication? STRICTLY NO (Pre-furnace only) STRICTLY NO (Pre-furnace only) STRICTLY NO (Pre-furnace only)
Heat Soak Testing (HST)Recommended to BS EN 14179 (NiS risk mitigation)Recommended to BS EN 14179 (NiS risk mitigation)Recommended to BS EN 14179 (NiS risk mitigation)
Next Procurement Step

Direct supply specification for cut-to-size toughened panels or local glazier installation quotes.

Read full technical specification

Specify interlayer performance requirements and reach qualified regional architectural laminators.

Read full technical specification

Calculate whole-window U-value and obtain commercial sealed unit supply quotations.

Read full technical specification
Performance figures based on European Standard test methodologies (EN 410, EN 673, EN ISO 717-1). Whole-system calculations required for Building Control sign-off.