BS EN 13501-2BS 476-22Approved Document B (Fire Safety)Scottish Technical Handbook Section 2Reviewed Technical Specification

Fire-Resistant Glazing Systems

Certified intumescent barrier assemblies engineered for Integrity (E), Radiation Control (EW), and Thermal Insulation (EI).

Engineering Definition: Specialist glass constructions incorporating clear intumescent interlayers that react at approximately 120°C, transforming into an opaque, rigid heat-shielding foam that prevents the spread of flames, smoke, and conductive heat transfer (BS EN 13501-2).
Material Construction Matrix

EI60 Multi-Ply Intumescent Fire-Resistant Glazing

Thermal Transmittance:3.4 W/m²K
Acoustic Reduction:Rw 44 dB
Explode Layers
1
Exposed Outer Float Ply(4mm Annealed Float)
4.0mm
2
Primary Intumescent Gel Core(Hydrated Sodium Silicate Gel)
3.0mm
3
Intermediate Glass Ply(4mm Float Core)
4.0mm
4
Secondary Intumescent Core(Hydrated Silicate Intumescent)
3.0mm
5
Unexposed Face Glass Ply(4mm Float)
4.0mm
Physical & Mechanical Performance Characteristics
Safety Class:Class 1B1 or 1C1 (BS EN 12600) on approved variants
Bending Strength:High integrity under thermal shock during fire conditions up to 1000°C furnace test curves
Thermal Shock Resistance:Designed to withstand standard EN 1363-1 ISO fire heating curve
Fracture Behaviour:Intumescent core holds assembly intact and creates insulating heat shield
Typical U-Value (Ug):2.8 to 4.5 W/m²K monolithic; down to 1.1 W/m²K when combined into an IGU
Acoustic Reduction (Rw):Rw 38 dB to Rw 47 dB (thick multi-ply intumescent layers provide exceptional acoustic attenuation)
Max Sheet Dimension:Restricted strictly by independent test certification fire scope reports (e.g. 1500mm × 3000mm)
Density & Mass:Substantially heavier: ~2.5 kg/m²/mm glass + ~1.4 kg/m² per mm intumescent gel

Key Architectural Advantages

  • •Life safety containment: prevents flashover and radiant heat ignition along protected escape routes and fire stairwells
  • •EI class ensures surface temperature on unexposed face does not exceed 140°C mean rise above ambient
  • •Dual compliance: delivers both life safety fire barrier and certified impact safety (BS EN 12600)

Critical Engineering Constraints

  • •CRITICAL: Glass cannot be installed into non-certified frames. Fire test certificate covers the ENTIRE SYSTEM ONLY (glass, frame, intumescent seals, fixings)
  • •Intumescent layers are sensitive to UV exposure and edge moisture; units for external use require integrated UV-absorbing PVB plies
  • •Substantial dead weight requires structural reinforcement of timber, steel, or aluminium fire-rated frames and floor slabs

Fabrication & Edge Processing Tolerances

Cut After Toughening:PROHIBITED (Catastrophic Fracture)
Heat Soak Testing (HST):Not Required

Most intumescent fire glasses must be cut only by licensed processing centers with certified edge-tape sealing equipment.

Architectural Specifier Checklist

Verify these technical criteria prior to contract documentation:

1Verify required classification: E (Integrity only), EW (Integrity + Radiation reduction <15 kW/m²), or EI (Integrity + Full Thermal Insulation).
2Demand supplier field of application test report (Certifire / Warringtonfire) matching exact proposed dimensions and orientation.
3Do NOT substitute standard toughened glass for fire-resistant glass; standard toughened shatters within 3 to 5 minutes in a fire.
Network Procurement Routing

GlassSuppliers.co.uk

Intended public marketplace destination for discovering regional glass processors, independent glaziers, and commercial installation contractors across the UK.

Recommended Action: Consult certified fire door and architectural fire screen specialist contractors with third-party test evidence.
Proceed to GlassSuppliers.co.uk
Reviewed by: Certified Fire Safety Glazing Consultant, BuyGlass Editorial Panel
Last Standard Verification: 2026-10-30